Standard

An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors. / Ignatyev, O. V.; Kosse, A. I.; Pulin, A. D. и др.
в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том 282, № 2-3, 01.10.1989, стр. 734-738.

Результаты исследований: Вклад в журналСтатьяРецензирование

Harvard

Ignatyev, OV, Kosse, AI, Pulin, AD, Shevchenko, YA & Shkola, NF 1989, 'An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Том. 282, № 2-3, стр. 734-738. https://doi.org/10.1016/0168-9002(89)90094-6

APA

Ignatyev, O. V., Kosse, A. I., Pulin, A. D., Shevchenko, Y. A., & Shkola, N. F. (1989). An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 282(2-3), 734-738. https://doi.org/10.1016/0168-9002(89)90094-6

Vancouver

Ignatyev OV, Kosse AI, Pulin AD, Shevchenko YA, Shkola NF. An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1989 окт. 1;282(2-3):734-738. doi: 10.1016/0168-9002(89)90094-6

Author

Ignatyev, O. V. ; Kosse, A. I. ; Pulin, A. D. и др. / An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors. в: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1989 ; Том 282, № 2-3. стр. 734-738.

BibTeX

@article{059e59121b634524a2447068d4948070,
title = "An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors",
abstract = "An updated system of program-controlled analog and analog-to-digital modules for X-ray spectrometers with semiconductor detectors is reported. Ways to increase the count rate capacity of pulse-drain feedback charge-sensitive preamplifiers to 106 cps for Ex = 5.9 keV are considered in detail. A new analog processor model AP-007 incorporating Kandiah's cusp-shaper is described. Some problems of further improvements in the modular system are discussed.",
author = "Ignatyev, {O. V.} and Kosse, {A. I.} and Pulin, {A. D.} and Shevchenko, {Yu. A.} and Shkola, {N. F.}",
year = "1989",
month = oct,
day = "1",
doi = "10.1016/0168-9002(89)90094-6",
language = "English",
volume = "282",
pages = "734--738",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2-3",

}

RIS

TY - JOUR

T1 - An updated system of electronic modules for X-ray spectrometers with cooled semiconductor detectors

AU - Ignatyev, O. V.

AU - Kosse, A. I.

AU - Pulin, A. D.

AU - Shevchenko, Yu. A.

AU - Shkola, N. F.

PY - 1989/10/1

Y1 - 1989/10/1

N2 - An updated system of program-controlled analog and analog-to-digital modules for X-ray spectrometers with semiconductor detectors is reported. Ways to increase the count rate capacity of pulse-drain feedback charge-sensitive preamplifiers to 106 cps for Ex = 5.9 keV are considered in detail. A new analog processor model AP-007 incorporating Kandiah's cusp-shaper is described. Some problems of further improvements in the modular system are discussed.

AB - An updated system of program-controlled analog and analog-to-digital modules for X-ray spectrometers with semiconductor detectors is reported. Ways to increase the count rate capacity of pulse-drain feedback charge-sensitive preamplifiers to 106 cps for Ex = 5.9 keV are considered in detail. A new analog processor model AP-007 incorporating Kandiah's cusp-shaper is described. Some problems of further improvements in the modular system are discussed.

UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=0024749480

UR - https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=tsmetrics&SrcApp=tsm_test&DestApp=WOS_CPL&DestLinkType=FullRecord&KeyUT=A1989AW92200092

U2 - 10.1016/0168-9002(89)90094-6

DO - 10.1016/0168-9002(89)90094-6

M3 - Article

VL - 282

SP - 734

EP - 738

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2-3

ER -

ID: 55655050