DOI

Iron-containing pharmaceuticals, namely: (i) PreNatal with ferrous fumarate, (ii) Tardyferon® with ferrous sulfate, (iii) Fenules with water free ferrous sulfate, (iv) Iron Complex with iron glycinate, citrate, (v) Gentle Iron, (vi) Hema-Plex® and (vii) Iron Bisglycinate with iron (ferrous) bisglycinate chelate (iron compounds are given as declared by the manufactures) were studied by 57Fe Mössbauer spectroscopy with X-ray diffraction and magnetization measurements for analysis of the iron state. The obtained results demonstrate that the iron compound announced by the manufacturer in each pharmaceutical is not homogeneous and exists as some modifications of this compound or results of its transformation/oxidation probably due to its instability. The presence of ferrous and ferric compounds is observed, and the relative ferric iron fractions are roughly determined for each pharmaceutical product. This analysis clearly shows the differences between the iron compounds proclaimed by the manufacturers and those obtained by Mössbauer spectroscopy. That justifies as to why this technique should be used for the control and analysis of the iron-containing pharmaceuticals.
Язык оригиналаАнглийский
Номер статьи115745
ЖурналJournal of Pharmaceutical and Biomedical Analysis
Том237
DOI
СостояниеОпубликовано - 2024

    Предметные области ASJC Scopus

  • Spectroscopy
  • Analytical Chemistry
  • Pharmaceutical Science
  • Drug Discovery
  • Clinical Biochemistry

    Предметные области WoS

  • Химия, Аналитическая
  • Фармакология и фармацевтика

ID: 46901465