Standard

An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures: book chapter. / Kalyakin, A.; Vylkov, A.; Gorbova, E. и др.
EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference: book. ред. / V. Cigolotti; C. Barchiesi; M. Chianella. ENEA, 2017. стр. 287-288.

Результаты исследований: Глава в книге, отчете, сборнике статейГлаваРецензирование

Harvard

Kalyakin, A, Vylkov, A, Gorbova, E, Medvedev, D, Demin, A, Tsiakaras, P & Volkov, A 2017, An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures: book chapter. в V Cigolotti, C Barchiesi & M Chianella (ред.), EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference: book. ENEA, стр. 287-288.

APA

Kalyakin, A., Vylkov, A., Gorbova, E., Medvedev, D., Demin, A., Tsiakaras, P., & Volkov, A. (2017). An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures: book chapter. в V. Cigolotti, C. Barchiesi, & M. Chianella (Ред.), EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference: book (стр. 287-288). ENEA.

Vancouver

Kalyakin A, Vylkov A, Gorbova E, Medvedev D, Demin A, Tsiakaras P и др. An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures: book chapter. в Cigolotti V, Barchiesi C, Chianella M, Редакторы, EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference: book. ENEA. 2017. стр. 287-288

Author

Kalyakin, A. ; Vylkov, A. ; Gorbova, E. и др. / An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures : book chapter. EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference: book. Редактор / V. Cigolotti ; C. Barchiesi ; M. Chianella. ENEA, 2017. стр. 287-288

BibTeX

@inbook{5e3cb6a5614f462a92da7e24e5cd1466,
title = "An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures: book chapter",
abstract = "In the present investigation an electrochemical method for the determination of concentration and diffusion coefficient of ammonia in nitrogen (NH3/N2) is proposed by the means of a solid-state amperometric sensor based on yttria-stabilized zirconia (8YSZ) electrolyte. The measured quantity of the studied sensor is limiting current. The experiments are performed for ammonia concentration levels of 0.1–5 vol% in the temperature interval of 375–430 °C. It is shown that the limiting current level is reached at temperature values not higher than 400 °C and it is linearly proportional to the ammonia concentration. This allows obtaining a calibration curve (limiting current vs. ammonia concentration) for the ammonia determination in NH3/N2 mixtures. Using the obtained results and diffusion channel parameters, coefficients of ammonia diffusion in nitrogen can also be calculated. It is found that these values are in a good agreement with table values. It is also found that under experimental conditions the ammonia electrochemical oxidation reaction leads to the formation of N2 rather than N2O or NO. The obtained results demonstrate the possibility of using such amperometric sensor for the analysis of ammonia-gas mixtures where diluent gas is nitrogen or another inert gas.",
author = "A. Kalyakin and A. Vylkov and E. Gorbova and D. Medvedev and A. Demin and P. Tsiakaras and A. Volkov",
note = "ACKNOWLEDGMENT The research was supported by the Ministry of Education and Science of the Russian Federation (contract no. 14.Z50.31.0001).",
year = "2017",
language = "English",
isbn = "978-888286324-1",
pages = "287--288",
editor = "V. Cigolotti and C. Barchiesi and M. Chianella",
booktitle = "EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference",
publisher = "ENEA",
address = "Switzerland",

}

RIS

TY - CHAP

T1 - An electrochemical method for the determination of concentration and diffusion coefficient of ammonia‑nitrogen gas mixtures

T2 - book chapter

AU - Kalyakin, A.

AU - Vylkov, A.

AU - Gorbova, E.

AU - Medvedev, D.

AU - Demin, A.

AU - Tsiakaras, P.

AU - Volkov, A.

N1 - ACKNOWLEDGMENT The research was supported by the Ministry of Education and Science of the Russian Federation (contract no. 14.Z50.31.0001).

PY - 2017

Y1 - 2017

N2 - In the present investigation an electrochemical method for the determination of concentration and diffusion coefficient of ammonia in nitrogen (NH3/N2) is proposed by the means of a solid-state amperometric sensor based on yttria-stabilized zirconia (8YSZ) electrolyte. The measured quantity of the studied sensor is limiting current. The experiments are performed for ammonia concentration levels of 0.1–5 vol% in the temperature interval of 375–430 °C. It is shown that the limiting current level is reached at temperature values not higher than 400 °C and it is linearly proportional to the ammonia concentration. This allows obtaining a calibration curve (limiting current vs. ammonia concentration) for the ammonia determination in NH3/N2 mixtures. Using the obtained results and diffusion channel parameters, coefficients of ammonia diffusion in nitrogen can also be calculated. It is found that these values are in a good agreement with table values. It is also found that under experimental conditions the ammonia electrochemical oxidation reaction leads to the formation of N2 rather than N2O or NO. The obtained results demonstrate the possibility of using such amperometric sensor for the analysis of ammonia-gas mixtures where diluent gas is nitrogen or another inert gas.

AB - In the present investigation an electrochemical method for the determination of concentration and diffusion coefficient of ammonia in nitrogen (NH3/N2) is proposed by the means of a solid-state amperometric sensor based on yttria-stabilized zirconia (8YSZ) electrolyte. The measured quantity of the studied sensor is limiting current. The experiments are performed for ammonia concentration levels of 0.1–5 vol% in the temperature interval of 375–430 °C. It is shown that the limiting current level is reached at temperature values not higher than 400 °C and it is linearly proportional to the ammonia concentration. This allows obtaining a calibration curve (limiting current vs. ammonia concentration) for the ammonia determination in NH3/N2 mixtures. Using the obtained results and diffusion channel parameters, coefficients of ammonia diffusion in nitrogen can also be calculated. It is found that these values are in a good agreement with table values. It is also found that under experimental conditions the ammonia electrochemical oxidation reaction leads to the formation of N2 rather than N2O or NO. The obtained results demonstrate the possibility of using such amperometric sensor for the analysis of ammonia-gas mixtures where diluent gas is nitrogen or another inert gas.

UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=85173572987

M3 - Chapter

SN - 978-888286324-1

SP - 287

EP - 288

BT - EFC 2017 - Proceedings of the 7th European Fuel Cell Piero Lunghi Conference

A2 - Cigolotti, V.

A2 - Barchiesi, C.

A2 - Chianella, M.

PB - ENEA

ER -