Standard

A fast signal processor for NaI(Tl) detectors. / Dudin, S. V.; Ignatyev, O. V. ; Pulin, A. D.
в: Nuclear Inst. and Methods in Physics Research, A, Том 352, № 3, 1995, стр. 610-613.

Результаты исследований: Вклад в журналСтатьяРецензирование

Harvard

Dudin, SV, Ignatyev, OV & Pulin, AD 1995, 'A fast signal processor for NaI(Tl) detectors', Nuclear Inst. and Methods in Physics Research, A, Том. 352, № 3, стр. 610-613. https://doi.org/10.1016/0168-9002(95)90014-4

APA

Vancouver

Dudin SV, Ignatyev OV, Pulin AD. A fast signal processor for NaI(Tl) detectors. Nuclear Inst. and Methods in Physics Research, A. 1995;352(3):610-613. doi: 10.1016/0168-9002(95)90014-4

Author

Dudin, S. V. ; Ignatyev, O. V. ; Pulin, A. D. / A fast signal processor for NaI(Tl) detectors. в: Nuclear Inst. and Methods in Physics Research, A. 1995 ; Том 352, № 3. стр. 610-613.

BibTeX

@article{0805451c9f9a4e5d8a270304f816f181,
title = "A fast signal processor for NaI(Tl) detectors",
abstract = "A spectroscopy CAMAC-module for fast analogue processing and analogue-to-digital conversion of pulses from NAI(Tl)-detectors and other slow scintillation detectors is reported. Input count-rate may be higher than 106 counts/s, output count-rate = 2.5 × 105 words/s. {\textcopyright} 1995.",
author = "Dudin, {S. V.} and Ignatyev, {O. V.} and Pulin, {A. D.}",
year = "1995",
doi = "10.1016/0168-9002(95)90014-4",
language = "English",
volume = "352",
pages = "610--613",
journal = "Nuclear Inst. and Methods in Physics Research, A",
issn = "0168-9002",
publisher = "Elsevier",
number = "3",

}

RIS

TY - JOUR

T1 - A fast signal processor for NaI(Tl) detectors

AU - Dudin, S. V.

AU - Ignatyev, O. V.

AU - Pulin, A. D.

PY - 1995

Y1 - 1995

N2 - A spectroscopy CAMAC-module for fast analogue processing and analogue-to-digital conversion of pulses from NAI(Tl)-detectors and other slow scintillation detectors is reported. Input count-rate may be higher than 106 counts/s, output count-rate = 2.5 × 105 words/s. © 1995.

AB - A spectroscopy CAMAC-module for fast analogue processing and analogue-to-digital conversion of pulses from NAI(Tl)-detectors and other slow scintillation detectors is reported. Input count-rate may be higher than 106 counts/s, output count-rate = 2.5 × 105 words/s. © 1995.

UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=5244338526

U2 - 10.1016/0168-9002(95)90014-4

DO - 10.1016/0168-9002(95)90014-4

M3 - Article

VL - 352

SP - 610

EP - 613

JO - Nuclear Inst. and Methods in Physics Research, A

JF - Nuclear Inst. and Methods in Physics Research, A

SN - 0168-9002

IS - 3

ER -

ID: 53461079