Anumerical simulation of the external heat exchange in a gas-electric glass-making furnace is examined. It is shown that the intensity of additional electric heating (AEH) of the glass mass affects the normal operation of the furnace. Examples of the calculation of the parameters of heat exchange as a function of the furnace productivity and AEH are presented.
Original languageEnglish
Pages (from-to)157-161
Number of pages5
JournalGlass and Ceramics (English translation of Steklo i Keramika)
Volume65
Issue number5-6
DOIs
Publication statusPublished - 1 May 2008

    ASJC Scopus subject areas

  • Materials Chemistry
  • Mechanics of Materials
  • Ceramics and Composites

    WoS ResearchAreas Categories

  • Materials Science, Ceramics

ID: 38892622