This article examines the sequence of calculation of losses in the current-conducting screen located in the air gap between the half-clutches of a magnetic clutch and heating up of the screen in sealed machines and devices when high-coercivity permanent magnets are packed loosely in the half-clutches of the magnetic clutch.
Original languageEnglish
Pages (from-to)392-397
Number of pages6
JournalChemical and Petroleum Engineering
Volume47
Issue number5-6
DOIs
Publication statusPublished - 1 Sept 2011