Standard

Analysis of indicators characterizing the reliability of cogeneration turbines. / Murmanskii, B. E.; Brodov, Yu. M.; Valamin, A. E. et al.
In: Thermal Engineering, Vol. 58, No. 1, 01.01.2011, p. 41-45.

Research output: Contribution to journalArticlepeer-review

Harvard

APA

Vancouver

Murmanskii BE, Brodov YM, Valamin AE, Kogan PV, Ioffe LS. Analysis of indicators characterizing the reliability of cogeneration turbines. Thermal Engineering. 2011 Jan 1;58(1):41-45. doi: 10.1134/S0040601511010101

Author

Murmanskii, B. E. ; Brodov, Yu. M. ; Valamin, A. E. et al. / Analysis of indicators characterizing the reliability of cogeneration turbines. In: Thermal Engineering. 2011 ; Vol. 58, No. 1. pp. 41-45.

BibTeX

@article{1d527e7ea149409281d1a372a726e800,
title = "Analysis of indicators characterizing the reliability of cogeneration turbines",
abstract = "Results from an analysis of indicators characterizing the reliability of cogeneration turbines produced by the ZAO Ural Turbine Works for a long time of their operation are presented. The most typical defects of cogeneration turbines that revealed themselves under field conditions are presented together with the main factors causing failures of the turbine as a whole and failures of its individual assemblies (parts).",
author = "Murmanskii, {B. E.} and Brodov, {Yu. M.} and Valamin, {A. E.} and Kogan, {P. V.} and Ioffe, {L. S.}",
year = "2011",
month = jan,
day = "1",
doi = "10.1134/S0040601511010101",
language = "English",
volume = "58",
pages = "41--45",
journal = "Thermal Engineering",
issn = "0040-6015",
publisher = "Pleiades Publishing",
number = "1",

}

RIS

TY - JOUR

T1 - Analysis of indicators characterizing the reliability of cogeneration turbines

AU - Murmanskii, B. E.

AU - Brodov, Yu. M.

AU - Valamin, A. E.

AU - Kogan, P. V.

AU - Ioffe, L. S.

PY - 2011/1/1

Y1 - 2011/1/1

N2 - Results from an analysis of indicators characterizing the reliability of cogeneration turbines produced by the ZAO Ural Turbine Works for a long time of their operation are presented. The most typical defects of cogeneration turbines that revealed themselves under field conditions are presented together with the main factors causing failures of the turbine as a whole and failures of its individual assemblies (parts).

AB - Results from an analysis of indicators characterizing the reliability of cogeneration turbines produced by the ZAO Ural Turbine Works for a long time of their operation are presented. The most typical defects of cogeneration turbines that revealed themselves under field conditions are presented together with the main factors causing failures of the turbine as a whole and failures of its individual assemblies (parts).