Standard

A setup for viscosity measurements of oxide melts by the Stokes method. / Panfilov, A.; Lyamkina, N. S.; Sotnikov, A. et al.
In: Instruments and Experimental Techniques, Vol. 45, No. 1, 2002, p. 135-137.

Research output: Contribution to journalArticlepeer-review

Harvard

Panfilov, A, Lyamkina, NS, Sotnikov, A & Zinovkin, A 2002, 'A setup for viscosity measurements of oxide melts by the Stokes method', Instruments and Experimental Techniques, vol. 45, no. 1, pp. 135-137. https://doi.org/10.1023/A:1014585201031

APA

Panfilov, A., Lyamkina, N. S., Sotnikov, A., & Zinovkin, A. (2002). A setup for viscosity measurements of oxide melts by the Stokes method. Instruments and Experimental Techniques, 45(1), 135-137. https://doi.org/10.1023/A:1014585201031

Vancouver

Panfilov A, Lyamkina NS, Sotnikov A, Zinovkin A. A setup for viscosity measurements of oxide melts by the Stokes method. Instruments and Experimental Techniques. 2002;45(1):135-137. doi: 10.1023/A:1014585201031

Author

Panfilov, A. ; Lyamkina, N. S. ; Sotnikov, A. et al. / A setup for viscosity measurements of oxide melts by the Stokes method. In: Instruments and Experimental Techniques. 2002 ; Vol. 45, No. 1. pp. 135-137.

BibTeX

@article{2a04056af29646a5869b8275ba490aae,
title = "A setup for viscosity measurements of oxide melts by the Stokes method",
abstract = "A setup ensuring direct viscosity measurements without preliminary calibration is described. The velocity of a ball moving in a melt was determined from the computer analysis of a digital X-ray-TV image of the cell. The measurement error reaches 6% at a ball velocity of 3.2 cm/s and decreases to 1.5% as the velocity falls down to 0.8 cm/s.",
author = "A. Panfilov and Lyamkina, {N. S.} and A. Sotnikov and A. Zinovkin",
year = "2002",
doi = "10.1023/A:1014585201031",
language = "English",
volume = "45",
pages = "135--137",
journal = "Instruments and Experimental Techniques",
issn = "0020-4412",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "1",

}

RIS

TY - JOUR

T1 - A setup for viscosity measurements of oxide melts by the Stokes method

AU - Panfilov, A.

AU - Lyamkina, N. S.

AU - Sotnikov, A.

AU - Zinovkin, A.

PY - 2002

Y1 - 2002

N2 - A setup ensuring direct viscosity measurements without preliminary calibration is described. The velocity of a ball moving in a melt was determined from the computer analysis of a digital X-ray-TV image of the cell. The measurement error reaches 6% at a ball velocity of 3.2 cm/s and decreases to 1.5% as the velocity falls down to 0.8 cm/s.

AB - A setup ensuring direct viscosity measurements without preliminary calibration is described. The velocity of a ball moving in a melt was determined from the computer analysis of a digital X-ray-TV image of the cell. The measurement error reaches 6% at a ball velocity of 3.2 cm/s and decreases to 1.5% as the velocity falls down to 0.8 cm/s.

UR - https://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=tsmetrics&SrcApp=tsm_test&DestApp=WOS_CPL&DestLinkType=FullRecord&KeyUT=000174664700029

UR - http://www.scopus.com/inward/record.url?partnerID=8YFLogxK&scp=0346364175

U2 - 10.1023/A:1014585201031

DO - 10.1023/A:1014585201031

M3 - Article

VL - 45

SP - 135

EP - 137

JO - Instruments and Experimental Techniques

JF - Instruments and Experimental Techniques

SN - 0020-4412

IS - 1

ER -

ID: 43816383