The article notes that to control the temperature distribution at the stock in blast furnaces, thermovision images are used, followed by automated processing of the information received. It has been experimentally established and computational and analytical studies have shown that in the blast furnace shaft there is a horizon at a depth of 3-5 m below the level of the fill, where the greatest sensitivity of the method for controlling irregularities in temperature fields is observed.
Translated title of the contributionPECULIARITIES OF THERMOVISION IMAGES CONTROLLING THE TEMPERATURES ON STOCK LEVEL IN THE BLAST FURNACE
Original languageRussian
Pages (from-to)12-14
Number of pages3
JournalСталь
Issue number4
Publication statusPublished - 2021

    Level of Research Output

  • VAK List
  • Russian Science Citation Index

    GRNTI

  • 53.00.00 METALLURGY

ID: 21910818